Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 Dec 2018 - 6 Feb 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
no
Remarks:
study conducted in a facility which operates in accordance with Good Laboratory Practice principles; however, no claim of GLP compliance was intended nor is made for this study
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
Octan-1-ol, ethoxylated
EC Number:
500-058-1
EC Name:
Octan-1-ol, ethoxylated
Cas Number:
27252-75-1
Molecular formula:
C10H22O2
IUPAC Name:
Octan-1-ol, ethoxylated
Test material form:
liquid

Results and discussion

Density
Type:
relative density
Density:
0.939 other: unitless
Temp.:
20 °C

Any other information on results incl. tables

The density ρ of the test item was calculated based on the ratio of the mass of test item to the mass of water used to fill the pycnometer using the following equation:

ρ = d(c-a)/(b-a)

Where: a - mass of pycnometer (g); b - mass of pycnometer filled with water (g); c - mass of pycnometer filled with test item (g); d - density of water at test temperature (kg/m³).

Measurement

Notation and unit

Determination

1

2

Mass of pycnometer

a (g)

17.3680

17.3686

Mass of pycnometer and purified water at 20 °C

b (g)

27.5550

27.6620

Mass of pycnometer and test item at 20 °C

c (g)

26.9504

27.0483

Density of water at 20 °C

d (kg/m³)

998.2

Density of test item

ρ (kg/m³)

939

939

Relative density D(20,4) is calculated using the following equation:

D =  ρ/(999.97 kg/m³)

where 999.97 kg/m³ is the density of water at 4 °C (CRC Handbook of Chemistry and Physics, 93rd Edition 2012-2013).

Applicant's summary and conclusion