Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4-6 Dec 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Qualifier:
according to guideline
Guideline:
other: Anon (2010), Explosive atmospheres – Part 20-1: Material characteristics for gas and vapour classification – test methods and data, Method of test for auto-ignition temperature.
Version / remarks:
IEC 60079-20-1:2010 P1-77
GLP compliance:
no
Remarks:
study conducted in a facility which operates in accordance with Good Laboratory Practice principles; however, no claim of GLP compliance was intended nor is made for this study

Test material

Constituent 1
Chemical structure
Reference substance name:
Octan-1-ol, ethoxylated
EC Number:
500-058-1
EC Name:
Octan-1-ol, ethoxylated
Cas Number:
27252-75-1
Molecular formula:
C10H22O2
IUPAC Name:
Octan-1-ol, ethoxylated
Test material form:
liquid

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
240 °C
Atm. press.:
>= 101 - <= 101.1 kPa

Any other information on results incl. tables

Results of the auto-ignition temperature determination are shown in the following table:

Temperature (°C)

Clean Flask (yes/no)

Volume (µL)

Ignition Delay (s)

Observations

200

Yes

70

> 300

No ignition. Grey fumes were emitted.

250

Yes

70

> 300

No ignition. Grey fumes were emitted.

300

Yes

70

< 1

A red/orange flame. Grey fumes were emitted.

280

No

70

4

A red/orange flame. Grey fumes were emitted.

270

No

70

7

A red/orange flame. Grey fumes were emitted.

260

No

70

12

An orange flame. Grey fumes were emitted.

258

No

70

13

An orange flame. Grey fumes were emitted.

254

No

70

17

An orange flame. Grey fumes were emitted.

252

No

70

14

An orange flame. Grey fumes were emitted.

250

Yes

200

23

A yellow/blue flame. Grey fumes were emitted.

248

Yes

200

24

A yellow/blue flame. Grey fumes were emitted.

246

Yes

200

29

A yellow/blue flame. Grey fumes were emitted.

244

Yes

200

34

A yellow/blue flame. Grey fumes were emitted.

242

Yes

200

36

A yellow/blue flame. Grey fumes were emitted.

240

Yes

200

55

A yellow/blue flame. Grey fumes were emitted.

238

Yes

200

> 300

No ignition. Grey fumes were emitted.

238

Yes

400

> 300

No ignition. Grey fumes were emitted.

238

Yes

600

> 300

No ignition. Grey fumes were emitted.

238

Yes

800

> 300

No ignition. Grey fumes were emitted.

238

Yes

1000

> 300

No ignition. Grey fumes were emitted.

Room temperature: 17 to 18 °C

Atmospheric pressure: 101.0 to 101.1 kPa

The test item has been determined to have an auto-ignition temperature of 240 °C.

Applicant's summary and conclusion