Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 20 June, 2015; Experimental completion date: 20 June, 2015; Study completion date: 23 July, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction; ISO 13320-1: Particle Size Analysis – Laser Diffraction Method
Deviations:
no
Principles of method if other than guideline:
Guidelines followed
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
- Identification: FAT 45082/I TE
- Lot.JL1101V5C (China)
- Appearance: Black powder
Mass median aerodynamic diameter:
ca. 4.942 µm
Percentile:
D10
Mean:
2.157 µm
Remarks on result:
other: Std deviation not specified
Key result
Percentile:
D50
Mean:
4.942 µm
Remarks on result:
other: Std deviation not specified
Percentile:
D90
Mean:
15.268 µm
Remarks on result:
other: Std deviation not specified

None

Conclusions:
The median particle size of FAT 45082/I was determined to be 4.94 μm.
Executive summary:

The particle size distribution of FAT 45082/I was analysed in a study conducted according to the internationally accepted guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose. Based on the findings of the study, median particle size (D50) of the substance was determined to be 4.94 μm, while the particle size D10 and D90 were 2.157 and 15.268 μm, respectively. 

Description of key information

The particle size distribution of FAT 45082/I was analysed in a study conducted according to the internationally accepted guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose. Based on the findings of the study, median particle size (D50) of the substance was determined to be 4.94 μm, while the particle size D10 and D90 were 2.157 and 15.268 μm, respectively.

Additional information