Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
31 May, 2008
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Name: HPCTP
Chemical name: Hexaphenoxycyclotriphosphazene
CAS number: 1184-10-7
Batch/Lot number: 190202
Description: White or light yellow crystal
Purity: 99.53%
Expiry date: 31 January 2021
Storage conditions: Controlled room temperature (15-25oC, ≤70% relative humidity)
Safety precautions: Routine safety precautions (gloves, goggles, face mask, lab coat) for unknown materials were applied to ensure personnel health and safety.
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In the preliminary test the test item melted and could not be ignited. Based on the results of the preliminary test, no main test was performed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is non-flammable in the conditions of this test.

Description of key information

The tests were negative. The test item is non-flammable in the conditions of this test.

Key value for chemical safety assessment

Additional information

Justification for classification or non-classification

In the preliminary test, the test item melted and could not be ignited. Since the tests were negative, it is non-flammable.