Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

No self ignition temperature of the test item was observed up to 423°C (corrected value)

Key value for chemical safety assessment

Additional information

The test to determine the self ignition temperature of MEXORYL SBF was conducted in compliance with the EU method A.16.

A sample of MEXORYL SBF was heated in an oven to 420 °C but no self-ignition of the substance was observed although the test was performed two times. Therefore, it was assumed that self ignition temperature of MEXORYL SBF is higher than 420 °C.

This result was considered as reliable without restrictions becauseit was in compliance with GLP and international guidelines.

As no self ignition temperature was observed down to 420°C, the result is expressed as a limit value, and cannot be retained as key data for purpose of CSA.