Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
experimental phase from 2014-02-28 to 2014-08-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. No major deviation was reported. The test substance is adequately characterised, with its isomers composition. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
yes
Remarks:
excess test item
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
yes
Remarks:
excess test item
Principles of method if other than guideline:
Testing was conducted in both double distilled water and daphnia reconstituted natural medium M4 (OECD 211).
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on June 3 to 5, 2013 / signed on November 5, 2013
Type of method:
flask method
Remarks:
modified acc. to Letinski et al. (2002) and OECD 123
Key result
Water solubility:
125 µg/L
Temp.:
20 °C
pH:
7
Remarks on result:
other: isomer 1 in distilled water (alpha.R,1R,6S)-
Key result
Water solubility:
285 µg/L
Temp.:
20 °C
pH:
7
Remarks on result:
other: isomer 2 in distilled water [1a(S*),6b]- (9Cl)
Water solubility:
115 µg/L
Temp.:
20 °C
pH:
7
Remarks on result:
other: isomer 1 in M4 medium (alpha.R,1R,6S)-
Water solubility:
261 µg/L
Temp.:
20 °C
pH:
7
Remarks on result:
other: isomer 2 in M4 medium [1a(S*),6b]- (9Cl)
Details on results:
The analytical method was validated and tested with satisfactory results in regard to linearity, accuracy, precision and specificity:
System quantification limit: 1 µg/L
Linearity: 1 – 50 µg test item/L (n=8), corresponding to 0.284 – 14.2 µg isomer 1/L and 0.652 – 32.6 µg isomer 2/L, r2 ranging between 0.9923 and 0.9998
LOQ (target): nominal 4 µg test item/L, corresponding to 1.14 µg isomer 1/L and 2.61 µg isomer 2/L
Recovery rates in pure water:
1 x LOQ = 93% for isomer 1, 92% for isomer 2 (RSD=4.2% and 3.7% resp.)
5 x LOQ = 97% for isomer 1, 100% for isomer 2 (RSD=6.7% and 7.2% resp.)
125 x LOQ = 93% for isomer 1, 90% for isomer 2 (RSD=12% and 9.6% resp.)
Recovery rates in daphnia medium (M4)
1 x LOQ = 91% for isomer 1, 87% for isomer 2 (RSD=0.7% and 4.6% resp.)
5 x LOQ = 105% for isomer 1, 105% for isomer 2 (RSD=1.8% and 2.1% resp.)
125 x LOQ = 90% for isomer 1, 94% for isomer 2 (RSD=4.0% and 6.4% resp.)
Specificity: Response of blank values of control samples was significantly lower than 30 % of LOQ, actually no higher signal than the background was observed.

For the water samples before centrifugation, no Tyndall effect was observed. For the M4 samples, the positive Tyndall-effect was also observed in pure, aged daphnia M4 medium with comparable intensity and therefore considered to be not caused by the test item.

The solubility of the test item in double distilled water and daphnia M4 medium was determined for un‑centrifuged and centrifuged samples.

Equilibrium was considered reached from 173 h after application.

Medium

Pretreatment

Isomer 1

Isomer 2

[µg/L]

[µg/L]

Double distilled water

545

1270

Double distilled water

centrifugation

125

  285

Daphnia M4 medium

506

1141

Daphnia M4 medium

centrifugation

115

  261

Isomer 1 = Cyclohexanepropanol, 2,2,6‑trimethyl‑a‑propyl‑, (alpha.R,1R,6S)
Isomer 2 =
Cyclohexanepropanol, 2,2,6‑trimethyl‑a‑propyl‑, [1a(S*),6b]‑ (9Cl)

The solubilities in the two test media did not differ significantly.

According to the sponsor, the difference between centrifuged and non-centrifuged samples show that, despite the slow-stirring procedure, the substance has tendency to oversaturate, and form stable emulsions. Therefore the results after centrifugation will be retained and considered as the true water solubility in the test conditions (i.e. loading of 0.1%). Moreover, despite all efforts to avoid the technical difficulties due to emulsification properties of the substance, the variability of results suggests that centrifugation may have not totally cleaned the aqueous phase, so the result should be considered as a maximum value. 

Regarding isomers distribution, the ratio isomer 2/isomer 1 is test item is 2.29 in the test item, and 2.28 or 2.27, based on measured concentrations in centrifuged samples, in water and M4 medium respectively, therefore no differential solubility between isomers is observed.

Conclusions:
Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)
Executive summary:

The water solubility of the test substance was determined according to OECD 105 / EC A.6 guideline, flask method, modified with slow stirring approach, in double distilled water and daphnia reconstituted medium M4, by measurement of the two isomers concentrations.

Samples were centrifuged due to tendency of the substance to form stable emulsions.

The analytical method (SPMEGCMS, external standard) for the determination of the test item was validated and tested with satisfactory results in regard to linearity, accuracy, precision and specificity.

Equilibrium was considered achieved from 173 h after application.

The results at 20°C and pH 7 were found to be 125 and 285 µg/L in water, and 115 and 261 µg/L in M4 medium, for the (alpha.R,1R,6S)- and for the [1a(S*),6b]‑ (9Cl) isomers, respectively (to be considered as maximum values).

The solubilities in the different test media did not differ significantly.

The isomer distribution of the solubility samples is comparable to that of the external standard.

Description of key information

In the test conditions (i.e. load.0.1%, 20°C, pH 7, equilibrium from 173h), the concentration of each isomer was:

125 µg/L for isomer 1 (alpha.R,1R,6S)- and 285 µg/L for isomer 2 [1a(S*),6b]- (9Cl) in double distilled water,

115 µg/L for isomer 1 (alpha.R,1R,6S)- and 261 µg/L for isomer 2 [1a(S*),6b]- (9Cl) in daphnia reconstituted medium M4.

Key value for chemical safety assessment

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EC method and under GLP, is available. Therefore it is considered as a key study.

However, despite all efforts to avoid the technical difficulties due to emulsification properties of the substance, the variability of results suggests that centrifugation may have not totally cleaned the water phase, so the results should be considered as maximum values.

Since no quantitative risk assessment has to be conducted for the present dossier, no single key value was retained. Moreover, as a multiconsituent substance, it is considered more relevant to express the results per individual isomer.