Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 28 October 1991 to 3 April 1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to the EEC Method A2 and it is GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: BS 4591:1971
Deviations:
no
GLP compliance:
yes
Type of method:
distillation method

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethyl 2-cyclohexylpropionate
EC Number:
412-280-5
EC Name:
Ethyl 2-cyclohexylpropionate
Cas Number:
2511-00-4
Molecular formula:
C11H20O2
IUPAC Name:
ethyl 2-cyclohexylpropanoate
Details on test material:
- Physical state: clear, colourless liquid
- Storage condition of test material: Dark at 4ºC

Results and discussion

Boiling point
Boiling pt.:
>= 218.4 - <= 225.1 °C
Atm. press.:
1 009 mBar

Any other information on results incl. tables

Analytical data are given in Table 3, showing distillation ranges between 218.5 -225.2ºC and 218.2 -225.0ºC for test 1 and test 2 respectively, from 5mL recovered to end point. The mean range is 218.4 -225.1. Recovery data are given in Table 4 and show a total recovery (distillate and residue) of 94.5 and 96.5 per cent for tests 1 and 2 respectively.

Table 3
Analytical data: boiling range
Distillation stage Thermometer reading (ºC) Mean temperature (ºC) Observation
Test 1 Test 2
Initial boiling point 214 213,9 213,9 This distillate was clear and colourless leaving behind a light brwon residue. White fumes were observed during the distillation.
5 ml recovered 218,5 218,2 218,4
10 ml recovered 219 219,5 219,3
20 ml recovered 221,4 221,6 221,5
30 ml recovered 223,6 223,2 223,4
40 ml recovered 224,4 224 224,2
50 ml recovered 224,5 224,4 224,5
60 ml recovered 224,5 224,5 224,5
70 ml recovered 224,7 224,6 224,7
80 ml recovered 224,8 224,6 224,7
90 ml recovered 225 224,8 224,9
95 ml recovered - 224,8 224,8
End point 225,2 225 225,1

Table 4
Recovery data: boiling range
Test Per cent recovery (Distillate) Per cent recovery (Residue) Per cent total recovery (Distillate + Residue)
1 93 1,5 94,5
2 95 1,5 96,5

Applicant's summary and conclusion

Conclusions:
The boling range of the test substance has been determined as 218.4 - 225.1ºC at 1009 mb, from 5mL recovered to the end point.
Executive summary:

The study was performed to determine the boiling point according to the EEC Method A2. The boling range of the test substance has been determined as 218.4 - 225.1ºC at 1009 mb.