Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25. July 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: study performed according to EU guideline but not under GLP conditions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Absorbent N grade A
IUPAC Name:
Absorbent N grade A
Details on test material:
- Name of test material (as cited in study report): Absorbent N grade A
- Substance type: UVCB
- Physical state: Brown liquid
- Stability under test conditions: months
- Storage condition of test material: room temperature, in the dark

Results and discussion

Flash point
Flash point:
< -5 °C
Atm. press.:
1 013.3 hPa

Any other information on results incl. tables

Individual Results

Weight / g

Flash point / °C

measured

Atmospheric
pressure / hPa

Flash point / °C

corrected

64.8

-4.8

1002.0

-4.53

70.2

-4.9

1002.0

-4.63

 

As the approximate value of the flash point was known the performance of the preliminary test was not necessary. In the main test the data points were determined by heating rate 1 K/min, as proposed in DIN EN ISO 13736.

The mean flash point corrected to 1013 hPa is -4.6 °C.

The final flash point rounded down with an accuracy of 0.5 °C is -5.0 °C.

Applicant's summary and conclusion

Conclusions:
The flash point of the test item is -5.0 °C under atmospheric conditions (1013.3 hPa).
Executive summary: