Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June-July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
yes
Type of method:
equilibrium method
Flash point apparatus:
other: Eraflash flash-point tester
Key result
Flash point:
104 °C
Atm. press.:
ca. 1 atm
Conclusions:
The Flash point of Cedarwood Texas oil distilled, Terpenes 2 (Thujopsene) is 104ºC at ca. 1 atm.
Executive summary:

The test item Cedarwood Texas oil distilled, Terpenes 2 (Thujopsene) is 104ºC at ca. 1 atm. according to the regulation EU Method A.9; ISO 2719; ISO 3679 and ASTM D93

Description of key information

Cedarwood Texas oil distilled - Terpenes 2 (Thujopsene) has a Flash point of 104ºC at ca. 1 atm.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information