Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 30 June 2011 and 01 July 2011.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Test material form:
liquid
Specific details on test material used for the study:
Sponsor's identification: FM0411M
Description: clear colourless viscous liquid
CAS number: 697234-76-7
Purity: 93.4% reactivity
Batch number: 1010142
Date received: 16 June 2011
Expiry date: 26 July 2011
Storage conditions: approximately 4°C in the dark

Results and discussion

Density
Type:
relative density
Density:
ca. 0.982
Temp.:
20.2 °C

Any other information on results incl. tables

Results

Results of duplicate determinations of relative density are shown in the following table:

Table 4.1

Measurement

Determination

1

2

Mass of pycnometer (g)

17.3316

16.8713

Mass of pycnometer and distilled water at 20.2ºC (g)

27.5132

27.2141

Mass of pycnometer and test item at 20.2ºC (g)

27.3484

27.0500

Density of water at 20.2ºC (kg/m3)

0.99816

0.99816

Density (kg/m3)

982.01

982.33

Relative density

0.98203

0.98235

Mean relative density:       0.982
Temperature:
                    20.2 ± 0.5ºC

 

Applicant's summary and conclusion

Conclusions:
The relative density of the test item has been determined to be 0.982 at 20.2 ± 0.5°C.
Executive summary:

INTRODUCTION

The relative density and surface tension of the test item have been determined.

Methods employed are designed to be compatible with those specified in the current OECD Guidelines for Testing of Chemicals.

Method

The determination was carried out using the pycnometer method, designed to be compatible with Method 109 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.

Conclusion

The relative density of the test item has been determined to be 0.982 at 20.2 ± 0.5°C.