Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
117.5 µm
Remarks on result:
other: no standard deviation reported
Percentile:
D10
Mean:
47 µm
Remarks on result:
other: no standard deviation reported
Key result
Percentile:
D50
Mean:
117.5 µm
Remarks on result:
other: no standard deviation reported
Percentile:
D90
Mean:
217.2 µm
Remarks on result:
other: no standard deviation reported
Conclusions:
Particle size distribution of the test item were as follows: L10D: 47 µm; L50D: 117.5 µm and L90D: 217.2 µm
Executive summary:

The particle size distribution of FAT 40171/Y TE was determined according to CIPAC MT 187. This was achieved using laser diffraction with dry dispersion method. Based on the findings of the study, the optical observations of the test item were as follows: L10D: 47 µm; L50D: 117.5 µm and L90D: 217.2 µm

Description of key information

Mass median aerodynamic diameter: 117.5 µm

Additional information

The particle size distribution of FAT 40171/Y TE was determined according to CIPAC MT 187. This was achieved using laser diffraction with dry dispersion method. Based on the findings of the study, the optical observations of the test item were as follows - L10D: 47 µm, L50D: 117.5 µm and L90D: 217.2 µm