Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 Dec 2018 - 6 Feb 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
no
Remarks:
study conducted at a facility which operates in accordance with Good Laboratory Practice principles; however, no claim of GLP compliance was intended nor is made for this study
Type of method:
method to determine freezing temperature
Remarks:
crystallizing point method

Test material

Constituent 1
Chemical structure
Reference substance name:
Octan-1-ol, ethoxylated
EC Number:
500-058-1
EC Name:
Octan-1-ol, ethoxylated
Cas Number:
27252-75-1
Molecular formula:
C10H22O2
IUPAC Name:
Octan-1-ol, ethoxylated
Test material form:
liquid

Results and discussion

Melting / freezing point
Melting / freezing pt.:
< -20 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
no
Sublimation:
no

Any other information on results incl. tables

First determination: cooling from 20.5 °C to -21 °C over t = 2190 s (ca. 36.5 min). The test item remained a clear, colourless mobile liquid.

Second determination: cooling from 20 °C to -21 °C over t = 2040 s (ca. 34 min). The test item remained a clear, colourless mobile liquid.

Atmospheric pressure was not reported (assumed normal, ca. 1013 hPa).