Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
solid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23.03.2013 -09.04.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: as mentioned below
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air.
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
open cup
Specific details on test material used for the study:
- Name of test material: 4-(4-Aminophenylazo)benzenesulphonic acid
- Molecular formula: C12H11N3O3S
- Molecular weight: 277.303 g/mol
- Smiles notation: S(c1ccc(\N=N\c2ccc(N)cc2)cc1)(O)(=O)=O
- InChl: 1S/C12H11N3O3S/c13-9-1-3-10(4-2-9)14-15-11-5-7-12(8-6-11)19(16, 17)18/h1-8H,13H2,(H,16,17,18)/b15-14+
- Substance type: organic
- Physical state: Solid
Key result
Flash point:
> 330 °C
Atm. press.:
970 hPa
Remarks on result:
other: The substance did not show flash point upto 330°C

Since the end point was not attained, it is concluded that this chemical was non flammable.

Conclusions:
The principle method used to determine the flash point property of the substance is open cup method. According to open cup considerations, test chemical did not show flash point upto 330°C and at atmospheric pressure 970 hPa,hence the flash point of test chemical was considered to be >330 degree C.
Executive summary:

The principle method used to determine the flash point property of the substance is open cup method. According to open cup considerations, test chemical did not show flash point upto 330°C and at atmospheric pressure 970 hPa,hence the flash point of test chemical was considered to be >330 degree C.

Description of key information

The principle method used to determine the flash point property of the substance is open cup method. According to open cupconsiderations, test chemical did not show flash point upto 330°C and at atmospheric pressure 970 hPa,hence the flash point of test chemical was considered to be >330 degree C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
330 °C

Additional information