Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 9, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature.
Key result
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0.001 Pa
Key result
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0.002 Pa

Vapour pressure at 20ºC and 25ºC was calculated on the basis of equation

log(p)=f(1/t)=a-b/(t+273.15)

where: p= vapour pressure in Pa, t=temperature in ºC, obtained for four measurements points: 90.9ºC, 95.7ºC, 100.4ºC and 105.2ºC.

 Temperature [ºC] (t)    Vapour pressure [Pa] (P)    Evaporation rate [µg/min]
 90.90 2.211 29.36 
 95.70 3.300  43.53
 100.40 4.781  62.66 
 105.20 7.210  93.90 

Equation ln(P)=a-b/(t+273,15) a= 13.8597 b= 4920.93 R2= 0.9933

Calculated values:

  Temperature [ºC]   Pressure [Pa]
 20  

1.18 x 10-3

 25  

2.26 x 10-3

Conclusions:
The determined vapour pressure of the test item was 0.00118 Pa at 20ºC and 0.00226 Pa at 25ºC.
Executive summary:

The vapour pressure of the test item was determined according to OECD 104 and EU method A.4, following GLP, using an apparatus with Knudsen cell. The determined vapour pressure of the test item was 0.00118 Pa at 20ºC and 0.00226 Pa at 25ºC.

Description of key information

Key study: OECD 104 and EU method A.4. GLP study. The determined vapour pressure of the test item was 0.00118 Pa at 20ºC and 0.00226 Pa at 25ºC.

Key value for chemical safety assessment

Vapour pressure:
0.002 Pa
at the temperature of:
25 °C

Additional information

Key study: The vapour pressure of the test item was determined according to OECD 104 and EU method A.4, following GLP, using an apparatus with Knudsen cell. The determined vapour pressure of the test item was 0.00118 Pa at 20ºC and 0.00226 Pa at 25ºC.