Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 950-492-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material: provided by Sponsor, Lot number 91112Y
- Purity.: 92.4%
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: The test sample was stored in a dark storage place at room temperature,
- Stability and homogeneity of the test material in the vehicle/solvent under test conditions (e.g. in the exposure medium) and during storage: stability
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing (e.g. warming, grinding): The test sample(50.1mg) was weighed with an electronic analytical balance and then filled up to10mL with tetrahydrofuran. This solution(1mL) was filled up to10mL with eluent for HPLC analysis to prepare a test item solution. Tetrahydrofuran(1mL) was filled up to 10mL with the eluent and the solution was used as a solvent blank. - Radiolabelling:
- no
- Test temperature:
- 25℃
- Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: LC-2010CHr(Built-in ultraviolet and visible spectrophotometer) (Shimadzu)
- Type: High-performance liquid chromatograph(No.LC-138)
- Type, material and dimension of analytical (guard) column: Inertsil CN-3(150mmx 2.1mm L.D., particle size 5um,GL Sciences)
MOBILE PHASES
Eluent : Methanol/purified water (65/35v/v)
DETERMINATION OF DEAD TIME
Retention time of test item(min)
REFERENCE SUBSTANCES
- Identity: Formamide (75-12-7); NN-Dimethyl benzamide 611-74-5; Atrazine 1912-24-9; Linuron 330-55-2; 1,2,3-Trichlorobenzene 87-61-6; Phenanthrene 85-01-8; DDT 50-29-3
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 2μl
- Quantity of reference substances: 2-10 μl
REPETITIONS
- Number of determinations: 2
EVALUATION
- Calculation of capacity factors k': k= (tR-t0)/t0
- Determination of the log Koc value: log Koc= a×log k+b - Type:
- log Koc
- Value:
- >= 3.87 - <= 4.61 dimensionless
- Temp.:
- 25 °C
- Remarks on result:
- other: pH : not specific
- Details on results (HPLC method):
- attachment
- Validity criteria fulfilled:
- yes
- Conclusions:
- The log Koc of the test item is 3.87-4.61.
- Executive summary:
HPLC method (OECD121, GLP. RL1) was applied to estimation of the Adsorption Coefficient(Koc)on soil and on sewage sludge of the test item. The test item is a multi- constituent substance, and two peaks of HPLC used for Koc analysis. The log Koc of the test item is 3.87-4.61.
Reference
Description of key information
The log Koc of the test item is 3.87-4.61.
Key value for chemical safety assessment
- Koc at 20 °C:
- 7 413
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.