Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Sept 1995 to 22 Dec 1995
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Deviation: The temperature during the measurement was 22 °C in deviation from the 20 °C recommended in Guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes
Type of method:
pycnometer method
Key result
Type:
density
Density:
1 570 kg/m³
Temp.:
22 °C
Remarks on result:
other:
Remarks:
Deviation ± 40 kg/m3. The indicated error is based on an accuracy of 0.05E-06 m3 for the volume measurement.

PRIMARY RESULTS OF EXPERIMENTS

Sample preparation:

- Sample has been dried for 3 h at a temperature of 50 °C.

- Weight of sample before drying: 9.92 g

- Weight of sample after drying: 9.90 g

Sample Weights:

- Weight of sample for analysis I: 6.248 g

- Weight of sample for analysis II: 3.507 g

Measured volumes:

Result for the volume of the test sphere (standard sphere of volume: 8.58E-06 m3

Results of successive volume measurements:

Sample

Analysis I (mL)

Analysis II (mL)

1.

4.26

2.53

2.

4.28

2.51

3.

4.27

2.51

mean

4.270

2.517

Blank

- 0.282

- 0.282

Effective volume

3.988

2.235

Conclusions:
The Density was 1.57E+03 kg/m3, corresponding to a relative density (P) of 1.57.
Executive summary:

To determine the density of the test item a study was performed according to EU Method A.3 in compliance with GLP. The density was determined to be 1.57E+03 kg/m3 (equivalent to 1.57 relative density) at 22 ºC.

Description of key information

Density: 1.57 E+03 kg/m3 (corresponding to a relative density Pr= 1.57), EEC A.3, pycnometer method, Füldner 1995

Key value for chemical safety assessment

Relative density at 20C:
1.57

Additional information