Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)

Test material

1
Reference substance name:
Reaction product of tin, citric acid and nitric acid
EC Number:
944-119-4
Molecular formula:
not available
IUPAC Name:
Reaction product of tin, citric acid and nitric acid
Test material form:
liquid
Details on test material:
Charge: 170001CAKO

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.65
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.14
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.35
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.94

Any other information on results incl. tables

Results in detail

Viscosity determination of the test item at 20 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

1.3527

1.6547

2nddetermination

1.3474

1.6482

Mean value

1.35

1.65

*) calculated with a density of the test item of ρ= 1.22328 g/ml

 

Viscosity determination of the test item at 40 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

0.9497

1.1461

2nddetermination

0.9378

1.1318

Mean value

0.94

1.14

*) calculated with a density of the test item of ρ= 1.20685 g/ml

The estimated accuracy is ± 1 %.