Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ASTM D92 (Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester)
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland Open Cup Tester
Remarks:
see "Overall remarks"
Key result
Flash point:
250 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: Pressure not reported. Ambient conditions (ca. 1013 hPa) can be assumed as the test was conducted using an open cup system.
Endpoint:
flash point of flammable liquids
Data waiving:
other justification
Justification for data waiving:
other:
Reason / purpose for cross-reference:
data waiving: supporting information

Description of key information

Flash point > 200.0 °C

Key value for chemical safety assessment

Additional information

The flash-point of the test substance was determined by Cleveland open cup method according ASTM D92. Since the measured flash-point is far above the classification limit and above 200 °C (250 °C) the open-cup method is accepted.