Registration Dossier

Administrative data

Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
Due to the low vapour pressure of the test item, which was calculated to be 1.24E-5 Pa at 20°C and 1.78E-5 Pa at 25°C, no exposure via inhalation is expected. Therefore, a study in acute inhalation toxicity can be omitted.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion