Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 14, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 500 °C
Atm. press.:
1 013 hPa

Melting point / melting range // boiling point / boiling range: Differential scanning calorimetry

The first DSC measurement in an aluminium crucible with a hole showed an endothermal effect in the temperature range of 70 – 160 °C. A 2nd measurement was conducted being stopped at 180 °C. It showed an endothermal effect within the temperature range 90 – 140 °C. After both measurements visual inspection showed that the test item was unchanged. The results of the DSC measurement are summarized in Table1.

Table1: DSC measurements

Ident No.

Test item /

mg

Starting temperature /

°C

Final test temperature /

°C

Temperature range /

°C

Crucible

Observations after the measurement

38037

16.64

25

500

70 – 160
(endothermal)

Aluminium with a hole

Test item was unchanged after the measurement; mass loss: 26 %

38038

21.28

25

180

90 – 140
(endothermal)

Aluminium with a hole

Test item was unchanged after the measurement; mass loss: 11 %

Under consideration of the result from the DSC measurement it was concluded that the test item had no melting point and no boiling point at atmospheric conditions.

Executive summary:

The test item had no melting point and no boiling point at atmospheric conditions.

Description of key information

The test item had no melting point and no boiling point at atmospheric conditions.

Key value for chemical safety assessment

Additional information