Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
November 09, 2010 - November 17, 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
not specified
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
140 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test item DMDS has a flash point of 140.0 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point.


Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 18, 2016 - March 02, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
141 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test item DMDS has a flash point of 141 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).



Executive summary:

The test item DMDS has a flash point of 141 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
141 °C

Additional information