Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 August 2017 - 20 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
column elution method

Test material

Constituent 1
Chemical structure
Reference substance name:
Yttrium trifluoride
EC Number:
237-257-5
EC Name:
Yttrium trifluoride
Cas Number:
13709-49-4
Molecular formula:
YF3
IUPAC Name:
yttrium trifluoride
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): yttrium trifluoride
- Physical state: solid
- Appearance: white powder
- Further information on test material confidential.

Results and discussion

Water solubilityopen allclose all
Key result
Water solubility:
< 0.03 mg/L
Conc. based on:
element (dissolved fraction)
Remarks:
Y
Temp.:
20 °C
pH:
6
Remarks on result:
other: Expressed as yttrium content in water; mean at flow rates of 12.5 mL/h and 25 mL/h.
Key result
Water solubility:
< 0.1 mg/L
Conc. based on:
test mat. (dissolved fraction)
Remarks:
Result calculated based on dissolved Y measurements.
Temp.:
20 °C
pH:
6
Remarks on result:
other: Mean at flow rates of 12.5 mL/h and 25 mL/h.
Details on results:
Results were validated by:
- Linearity validation: The analysis showed a good linearity of the method (r > 0.99).
- Accuracy validation: Results in dilution mixture showed a good accuracy which indicates acceptable data (recoveries ranged between 70 and 110%).
- Repeatability validation: The results indicated a good precision of the data (RSD < 20%).
- Specificity: The intensity (CPS) of blank samples measured was negligible.
- Limit of quantification: 0.015 mg Y/L
- Limit of detection: 0.005 mg Y/L

Any other information on results incl. tables

Results of the preliminary test with milliQ water and at pH 6 were:

Amount of test item weighed (g) 0.1 0.1 0.1 0.1 0.1 0.1  0.01
Volume of water added (mL) 0.1 0.5 1 2 10 100 1000
Solubility (yes/no) No No  No  No No  No No (after > 96 h of agitation of the test solution)

Results of the main test:

 

Solubility expressed as

yttrium content in water

(mg/L)

Solubility of yttrium fluoride in water

(mg/L)

Mean pH measured

Temperature

(°C)

Test 1

(flow 25 mL/h)

 < 0.02

 < 0.03

 6

 20

Test 2

(flow 25 mL/h)

 0.03  0.05  6  20
Mean (Test 1 and Test 2)  < 0.03  < 0.05  6  20

Test 3

(flow 12.5 mL/h)

 0.03

 < 0.05

 6

 20

Mean (12.5 mL/h and 25 mL/h)

 < 0.03  < 0.05 rounded at < 0.1  6  20

Applicant's summary and conclusion

Conclusions:
The water solubility of yttrium trifluoride was determined to be < 0.1 mg/L at pH 6 and at 20°C. This result was calculated from the measured yttrium content in water which was < 0.03 mg/L (column elution method).