Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-726-8 | CAS number: 7704-98-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- other: Internal data
- Remarks:
- SAP extract
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 13320 (Particle size analysis - Laser diffraction methods)
- Version / remarks:
- Internal Company method
- Principles of method if other than guideline:
- - Basic principle
This method of measurement is based on the interaction between light beams and solid particles. Under the assumption of spherical particles, a laser diffraction pattern can be used to deduce the particle size distribution within a sample.
- Apparatus
Cilas granulometer
Measuring range: 0.04-2500 μm
- Procedure
The sample is suspended in a suitable liquid, if necessary, under the addition of a dispersion agent. The suspension is homogenized by stirring and treatment with ultrasound and subsequently pumped through a cuvette. The cuvette is simultaneously radiated by a helium-neon-laser. The light diffraction pattern resulting from the interaction of laser beam and solid particles is detected by a photomultiplier and converted into a particle size distribution by a processor unit. - Type of method:
- Laser scattering/diffraction
- Key result
- Percentile:
- D50
- Mean:
- ca. 3.662 µm
- Remarks on result:
- other: SAP extract
- Conclusions:
- The granulometry of TiH2 has been determined using Laser diffraction (Internal Company method). D50 was 3.662 µm (mean value).
Reference
Description of key information
The granulometry of TiH2 has been determined using Laser diffraction (Internal Company method). D50 was 3.662 µm.
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
