Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Justification for type of information:
According to Regulation EC No. 440/2008, A.10, Section 1.1, the test procedure is applicable to powdery, granular or paste-like substances. Method A.11 applies to gases. As this substance is not a solid or gas, its flammability will be assessed by flash point methods applicable to liquid materials.

Description of key information

Waiver

Key value for chemical safety assessment

Flammability:
not classified

Additional information

According to Regulation EC No. 440/2008, A.10, Section 1.1, the test procedure is applicable to powdery, granular or paste-like substances. Method A.11 applies to gases. As this substance is not a solid or gas, its flammability will be assessed by flash point methods applicable to liquid materials.

Justification for classification or non-classification

The substance is not flammable. The measured flash point of this liquid substance is 130.6 °C. As this is above the limit flash point value of 60 °C which results in classification of a liquid as flammable according to Regulation EC No. 1272/2008, the substance is not classified.