Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Justification for type of information:
Guideline method conducted in a reliable laboratory within the spirit of GLP, but without CLP certification.
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
Method: DIN EN ISO 2719 Determination of flash point-Pensky-Martens closed cup method.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
130.5 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Assume standard atmospheric pressure.

The flash point of ZWA 5496 is 130.5 oC.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance is 130.5 °C. As this is above the limit flash point value of 60 °C which results in classification of a liquid as flammable according to Regulation EC No. 1272/2008, the substance is not classified.

Description of key information

130.5 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
130.5 °C

Additional information