Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed prior to OECD guideline and GLP principles but follows principles thereof.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1981
Report date:
1981

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CFR 16, 4500.42
Deviations:
no
Principles of method if other than guideline:
Method: Draize Test
GLP compliance:
no
Remarks:
Study was perfomed prior to GLP settings

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2,6,6-tetramethyl-4-piperidylamine
EC Number:
253-197-2
EC Name:
2,2,6,6-tetramethyl-4-piperidylamine
Cas Number:
36768-62-4
Molecular formula:
C9H20N2
IUPAC Name:
2,2,6,6-tetramethylpiperidin-4-amine
Details on test material:
Name of test material (as cited in study report): Triacetondiamin
- Substance type: colourless liquid with low viscosity
- Physical state: liquid
- Analytical purity: no data

Test animals / tissue source

Species:
rabbit
Strain:
New Zealand White
Details on test animals or tissues and environmental conditions:
TEST ANIMALS
- Source: J. Scheele, Büdrich/Westfalen, Werl, Germany
- Housing: individually
- Diet: ad libitum
- Water: ad libitum


ENVIRONMENTAL CONDITIONS
Temperature: 21-23°C
climated rooms
light circle dark/light: 12/12

Test system

Vehicle:
unchanged (no vehicle)
Controls:
not required
Amount / concentration applied:
undiluted
Amount applied: 0.1 ml
Duration of treatment / exposure:
Single instillation into the conjunctival sac; The test item was placed in the conjunctival sac of the right eye of each animal after gently pulling the lower lid away from the eyeball. The lids were then gently held together for about one second in order to prevent loss of the material. The left eye, which remained untreated, served as a control. No rinsing was performed.
Observation period (in vivo):
Due to the observed effects all animals were killed after 24 h after application for human reasons
Number of animals or in vitro replicates:
6
Details on study design:
REMOVAL OF TEST SUBSTANCE
- Washing: no

SCORING SYSTEM:
According to Appraisal of the Safety of Chemicals in Foods, Drugs and Cosmetics published by the Food and Drug Officialy of the United States, 1959

TOOL USED TO ASSESS SCORE: no

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
mean
Time point:
other: 24 h
Score:
4
Max. score:
4
Remarks on result:
other: animals killed after 24 h for human reasons
Irritation parameter:
iris score
Basis:
mean
Time point:
other: 24h
Score:
> 2
Max. score:
2
Remarks on result:
other: not assessable
Irritation parameter:
conjunctivae score
Remarks:
redness and chemosis
Basis:
mean
Time point:
other: 24 h
Score:
> 4
Max. score:
4
Remarks on result:
other: black discolouration
Irritant / corrosive response data:
total irritation could not be calculated. After 24 h, high-grade irritation associated with strong swelling and black-coloured necrosis of the conjunctivae as well as complete opacity of the corneas in all animals.

Applicant's summary and conclusion

Interpretation of results:
Category I
Remarks:
Migrated information Criteria used for interpretation of results: OECD GHS
Conclusions:
Six rabbits exposed for 24 hours to 0.1 mL test substance in the conjuncital sac revealed high-grade irritation associated with strong swelling and black-coloured necrosis of the conjunctivae as well as complete opacity of the corneas in all animals. Therefore, under conditions tested, the test substance is regarded to be corrosive.