Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable, guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN EN ISO 2592
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Cyclohexane, oxidized, non-acidic by-products, distn. residues
EC Number:
271-816-4
EC Name:
Cyclohexane, oxidized, non-acidic by-products, distn. residues
Cas Number:
68609-04-1
IUPAC Name:
(1s,4s)-cyclohexane-1,4-diol (cyclohexyloxy)cyclohexane 2-butylcyclohexan-1-one 8-oxatricyclo[7.4.0.0^{2,7}]trideca-1(9),2(7)-diene cyclohexane cyclohexane-1,3-diol cyclohexanol phenol hydrate
Details on test material:
Name of test material (as cited in study report): Cyclohexane, oxidized, non-acidic by-products, distn. residues
Analytical purity:pure

Results and discussion

Any other information on results incl. tables

1.) DIN EN ISO 2719 (closed cup): flashpoint not detectable; ignition flame goes out at 109 °C.

2.) DIN EN ISO 2592 (open cup): flashpoint = 124 °C.

Applicant's summary and conclusion