Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
supporting study
Study period:
Between 12 February and 21 April 2012.
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Cited from ECHA disseminated dossier Query date: 2015-07-22 For justification of read across please refer to IUCLID section 13.

Data source

Reference
Reference Type:
other: ECHA disseminated dossier
Title:
No information
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Principles of method if other than guideline:
The test system consisted of a high performance liquid chromatograph with a suitable detector (UV/VIS). A reverse phase HPLC column with a very low percentage of polar groups was used (e.g. C8, C18). The mobile phase contained at least 25% aqueous phase.
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Reference substance name:
939-183-5
EC Number:
939-183-5
IUPAC Name:
939-183-5
Details on test material:
Identification: ERC#18
Description: clear colorless liquid
Batch: 9114460/002
Purity: 100% (UVCB)
Expiry / Retest Date: 23 January 2013
Storage Conditions: room temperature in the dark

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
> 6.5
pH:
6.74

Any other information on results incl. tables

Results

Preliminary estimate

The log10Powwas calculated to be:    5.50 to 6.48
The full KOWWIN calculation is presented in Appendix 2(Attachment 3 of this summary).

Definitive Test

Please see Attachment 4 for Typical Chromatography.

Calibration

 

The retention times of the deadtime and the retention times, capacity factors (k') and log10Powvalues for the reference standards are shown in the following tables:

 

Table 1

 

Dead Time

Retention Time (mins)

Mean Retention Time (mins)

Injection 1

Injection 2

Thiourea

2.507

2.512

2.510

 

Table 2

 

Standard

Retention Time (mins)

Mean Retention Time (mins)

Capacity Factor (k')

Log10k'

Log10Pow

 

Injection 1

Injection 2

 

 

 

 

Benzene

4.475

4.480

4.478

0.784

-0.106

2.1

Toluene

5.583

5.588

5.586

1.23

8.83 x 10-2

2.7

Naphthalene

6.351

6.361

6.356

1.53

0.185

3.6

Phenanthrene

9.665

9.684

9.674

2.86

0.456

4.5

Triphenylamine

21.312

21.336

21.324

7.50

0.875

5.7

DDT

30.943

30.948

30.945

11.3

1.05

6.5

Partition coefficient of sample

 

The retention times, capacity factor and log10Powvalue determined for the sample are shown in the following table:

 

Table 3

 

Peak

Injection

Retention Time (mins)

Capacity Factor (k')

Log10k'

Log10Pow

1

1

42.460

> 11.3

> 1.05

> 6.5

2

42.431

> 11.3

> 1.05

> 6.5

2

1

43.487

> 11.3

> 1.05

> 6.5

2

43.522

> 11.3

> 1.05

> 6.5

3

1

43.881

> 11.3

> 1.05

> 6.5

2

43.894

> 11.3

> 1.05

> 6.5

4

1

44.273

> 11.3

> 1.05

> 6.5

2

44.303

> 11.3

> 1.05

> 6.5

 

Overall log10Pow:        > 6.5
Partition coefficient:  > 3.16 x 106

 

Applicant's summary and conclusion

Conclusions:
The partition coefficient of the test item has been determined to be greater than 3.16 x 10E6, log10 Pow > 6.5.
Executive summary:

The determination was carried out using the HPLC Method designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

 

The test system consisted of a high performance liquid chromatograph with a suitable detector (UV/). A reverse phase HPLC column with a very low percentage of polar groups was used (e.g. C8, C18). The mobile phase contained at least 25% aqueous phase.

The partition coefficient of the test item has been determined to be greater than 3.16 x 106, log10 Pow> 6.5.