Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 Mar 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study (EU A.1) with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Principles of method if other than guideline:
DSC measurement according to company guideline.
Type of method:
thermal analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Decomposition:
yes
Decomp. temp.:
ca. 288 °C

Any other information on results incl. tables

There is no endothermic effect (melting/boiling) in the DSC curves before decomposition.

The product starts to decompose in the sealed vial at ca. 288 °C with a mean energy of 101 J/g (2 measurements).

Applicant's summary and conclusion

Conclusions:
The test substance does not melt. Decomposition takes place at ca. 288 °C.
Executive summary: