Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles. No GLP lab.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 56
Principles of method if other than guideline:
According to ASTM D 56.
GLP compliance:
no
Remarks:
No GLP certified lab
Type of method:
closed cup
Key result
Flash point:
39 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point at 1 atm is 39°C according to ASTM D 56 methodology.
Executive summary:

The measured flash point at 1 atm is 39°C according to ASTM D 56 methodology.

Description of key information

The flash point is above 36°C at 1 atm.

Key value for chemical safety assessment

Additional information