Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Classification & Labelling & PBT assessment

GHS

General Information

Implementation:
EU
Remarks:
Environmental classification was agreed at EU level in 2005 as N, R51-53 (Commission Working Group, Pesticides and new chemicals September 28 -30, 2005).
The ECHA Committee for Risk Assessment in its opinion of Sept. 3 2010 proposed a harmonized classification of the substance as carcinogen category 2 (CLP) H351 or category 3 according to Dir. 67/548/EEC with R40 and S (2)-36/37. The committee reviewed carcinogenicity and reproductive toxicity data and came to the conclusion that no classification for reproductive toxicity was proposed as there is insufficient evidence for classification of TDCP as a male reproductive toxicant. Based on two developmental toxicity studies in rats the committee came to the conclusion that no classification for developmental toxicity is proposed as there was no evidence of embryotoxicity in the absence of maternal toxicity.

Related composition

Related composition:

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Reason for no classification:
hazard class not assessed
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Reason for no classification:
data conclusive but not sufficient for classification
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Reason for no classification:
data lacking
Desensitized explosives
Reason for no classification:
data lacking
Acute toxicity - oral
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - dermal
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - inhalation
Reason for no classification:
data conclusive but not sufficient for classification
Skin corrosion / irritation
Reason for no classification:
data conclusive but not sufficient for classification
Serious eye damage / eye irritation
Reason for no classification:
data conclusive but not sufficient for classification
Respiratory sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Skin sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Aspiration hazard
Reason for no classification:
data lacking
Reproductive toxicity
Reason for no classification:
data conclusive but not sufficient for classification
Effects on or via lactation
Reason for no classification:
data lacking
Germ cell mutagenicity
Reason for no classification:
data conclusive but not sufficient for classification
Carcinogenicity
Hazard category:
Carc. 2
Hazard statement:
H351: Suspected of causing cancer <state route of exposure if it is conclusively proven that no other routs of exposure cause the hazard>.
1. Specific target organ toxicity - single (STOT-SE)
Reason for no classification:
data lacking
1. Specific target organ toxicity - repeated (STOT-RE)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data lacking
Hazardous to the aquatic environment (long-term)
Hazard category:
Aquatic Chronic 1
Hazard statement:
H410: Very toxic to aquatic life with long lasting effects.
M-Factor chronic:
10
Hazardous to the ozone layer
Reason for no classification:
data conclusive but not sufficient for classification

Labelling

Signal word:
Warning

Hazard statements

H351: Suspected of causing cancer <state route of exposure if it is conclusively proven that no other routs of exposure cause the hazard>.
H410: Very toxic to aquatic life with long lasting effects.

Precautionary statements

P202: Do not handle until all safety precautions have been read and understood.
P273: Avoid release to the environment.
P281: Use personal protective equipment as required.
P308+P313: IF exposed or concerned: Get medical advice/attention.
P391: Collect spillage.
P405: Store locked up.
P501: Dispose of contents/container to ...

Notes