Registration Dossier

Diss Factsheets

Classification & Labelling & PBT assessment

GHS

Currently viewing:

General Information

Implementation:
EU
Type of classification:
self-classification
Remarks:

The streams within Category H are flammable liquids either H224, H225, or H226 (depending on the flash point and / or the boiling point).

Related composition

Related composition:
Boundary Composition & SIP

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Reason for no classification:
hazard class not assessed
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Hazard category:
Flam. Liquid 1
Hazard statement:
H224: Extremely flammable liquid and vapour.
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Reason for no classification:
data conclusive but not sufficient for classification
Desensitized explosives
Reason for no classification:
data lacking
Acute toxicity - oral
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - dermal
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - inhalation
Reason for no classification:
data conclusive but not sufficient for classification
Skin corrosion / irritation
Reason for no classification:
data conclusive but not sufficient for classification
Serious eye damage / eye irritation
Reason for no classification:
data conclusive but not sufficient for classification
Respiratory sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Skin sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Aspiration hazard
Reason for no classification:
data conclusive but not sufficient for classification
Reproductive toxicity
Reason for no classification:
data conclusive but not sufficient for classification
Effects on or via lactation
Reason for no classification:
data conclusive but not sufficient for classification
Germ cell mutagenicity
Reason for no classification:
data conclusive but not sufficient for classification
Carcinogenicity
Reason for no classification:
data conclusive but not sufficient for classification
1. Specific target organ toxicity - single (STOT-SE)
Reason for no classification:
data conclusive but not sufficient for classification
1. Specific target organ toxicity - repeated (STOT-RE)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (long-term)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the ozone layer
Reason for no classification:
data lacking

Labelling

Signal word:
Danger

Hazard pictogram

GHS02: flame

Hazard statements

H224: Extremely flammable liquid and vapour.

Precautionary statements

P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233: Keep container tightly closed.
P240: Ground and bond container and receiving equipment.
P241: Use explosion-proof [electrical/ventilating/lighting/...] equipment.
P242: Use non-sparking tools.
P243: Take actions to pevent static discharges.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P370+P378: In case of fire: Use... to extinguish.
P403+P235: Store in a well-ventilated place. Keep cool.
P501: Dispose of contents/container to ...

Notes