Registration Dossier

Diss Factsheets

Physical & Chemical properties

Storage stability and reactivity towards container material

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Hazardous Reactivities & Incompatibilities properties are reported:
- VIOLENT REACTION WHEN MIXED WITH (BROMINE & OXYGEN) OR (CHLORINE TRIFLUORIDE & WATER).
- Partial oxidation of a gasoline fraction in an autoclave under oxygen, initially at 22 bar and 100 deg C, ran wild and exploded; several smaller reactions had proceeded uneventfully.
- Interaction of the reactants (pre-mixed at -196 deg C) during warming to -78 deg C, then ambient temperature, exploded. Progressive addition of the alkene to the perchlorate at -78 was uneventful.

Additional information