EC number: 213-110-0 | CAS number: 924-88-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
General information: Immediately remove any clothing soiled by the product
After inhalation: Supply fresh air; consult doctor in case of complaints
After skin contact: Immediately wash with water and soap and rinse thoroughly
After eye contact: Seek medical treatment
After swallowing: Immediately call a doctor
Fire-fighting measures
Suitable extinguishing agents: Alcohol resisitant foam, fire-extinguishing powder, carbon dioxide
for safety reasons unsuitable extinguishing agents: no restrictions in large fires
In case of fire the following can be released: carbon monoxide (CO)
Protective equipment: Wear self-contained respiratory protective device; chemical resistant protective suit; under the protective suit a fire protective suit acc. to EN 469 should be applied.
Accidental release measures
Person related safety precautions:
Keep away from ignition sources.
Wear protective equipment
Keep unprotected persons away
Use respiratory protective device against the effects of fumes / dust / arerosols
Avoid contact with eyes and skin
Avoid spilling of product into the environment
Access only for trained personnel with personal protective equipment
Measure for environmental protection:
Do not allow to enter sewers / surface or ground water
Do not allow product to reach sewage systems or any water course
Keep contaminated washing water and dispose off appropriately
Mesaure for cleaning / collecting:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
Additional information:
Discharge into waste water channels and biological treatment plants only after clearance with the operating company and in accordance with local authority approval.
Handling and storage
Information for safe handling:
Keep containers tightly sealed
Fill only in dedicated and assigned containers
Requirements to be met by storerooms and receptacles:
Store in a cool location
Corrosion of metals:
It should generally be borne in mind that there is a possibility of corrosion on contact with this material. Resistance should be checked in each individual case.
Information about storage in one common storage facility:
Store away from oxidising agents
Recommended storage temperature:
It is recommended not to exceed room temperature during storage over a longer periode of time.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- no dangerous good according to transport regulations
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- no dangerous good according to transport regulations
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- no dangerous good according to transport regulations
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- no dangerous good according to transport regulations
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Sufficient ventilation is recommended.
Check seals on flanges and valves for suitability and corrosion resistance. if necessary inspection intervals should be defined!
General protective and hygienic measures:
The usual precautionary measures for handling chemicals should be followed.
Protection of hands:
Protective gloves - selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.
Do not wear gloves made from the following materials longer than 8 hours:
Butyl rubber, BR
Check for tightness before use.
Replace damaged gloves.
Not suitable glove materials:
Nitrile rubber, NBR
Natural rubber, NR
Chloroprene rubber, CR
PVC gloves
Eye protection:
Safety glasses
Body protection:
Use only liquid proof and chemical resistant protective suit.
Stability and reactivity
No decomposition if used according to specifications.
Materials to be avoided:
Strong bases, strong oxidising agents
Dangerous reactions:
No dangerous reactions known.
Dangerous products of decomposition:
Carbon monoxide (CO) and carbon dioxide (CO2)
Disposal considerations
Recommondation:
Must be specially treated adhering to official regulations
European waste catalogue: 07 07 99 - wastes not otherwise specified
Packagings that cannot be cleaned are to be disposed of in the same manner as the product.
Dispose of containers and unused contents in accordance with federal, state and local requirements.
Avoid spillage of product into the environment.
If possible use this material only in closed systems and devices. In case of open plant systems (sampling devices, filling and discharging, cleansing
works etc.) use local exhaust and collecting trays. Follow emission limit values. Measures in case of unwanted emissions should be established.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.