Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
26 Sept 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certifcate of Analysis
Qualifier:
according to guideline
Guideline:
other: ER020120 (internal method)
GLP compliance:
no
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
31.6
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
88.2
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7042
Principles of method if other than guideline:
Stabinger viscosimeter
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
88.18
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
31.62

Sample/Temperature (°C)

at 20 °C

at 40 °C

Viscosity 1 (mm²/s)

88.137

31.620

Viscosity 2 (mm²/s)

88.248

31.617

Viscosity 3 (mm²/s)

88.164

31.618

Mean (mm²/s)

88.183

31.618

 

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
10 Oct 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
other: ASTM D445
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
other: 25.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
66
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
32

Description of key information

88.2 mm²/s at 20 °C

Key value for chemical safety assessment

Viscosity:
88.2 mm²/s (static)
at the temperature of:
20 °C

Additional information

The static viscosity of the substance propane-1,2,3-triyl 3,5,5-trimethylhexanoate (CAS 56554-53-1) was determined by Stabinger viscosimeter according to ASTM D7042.