Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
4-(4-nitrophenyl)morpholin-3-one
EC Number:
610-199-1
Cas Number:
446292-04-2
Molecular formula:
C10 H10 N2 O4
IUPAC Name:
4-(4-nitrophenyl)morpholin-3-one
Details on test material:
Batch no.: BXR2LPC

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
0.95
Temp.:
40 °C
pH:
7

Any other information on results incl. tables

In order to comply with the demand of EG-guideline 92/69, the nonionic form of the test item and considering enviromental relevance, pH 7 was chosen as pH value for the buffer.

The reference log Pow-values in the OECD-guideline presumably refer to 25°C. The column temperature was 40°C. However, the influence of this temperature difference on the calculated log P value lies within the range of the error of the method.

Applicant's summary and conclusion