Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-06-25
Reliability:
1 (reliable without restriction)
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules and CIPAC MT 169 Tap Density of Water Dispersible Granules
Deviations:
no
Principles of method if other than guideline:
NA
GLP compliance:
yes (incl. QA statement)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Details on test material:
Batch no: 002FL08;

Results and discussion

Particle size
Percentile:
D50
Mean:
>= 250 - < 2 000 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
63 µm
Distribution:
0.1 %
No.:
#2
Size:
125 µm
Distribution:
1.4 %
No.:
#3
Size:
250 µm
Distribution:
14.7 %
No.:
#4
Size:
500 µm
Distribution:
67 %
No.:
#5
Size:
1 000 µm
Distribution:
15.7 %
No.:
#6
Size:
2 000 µm
Distribution:
0.1 %
No.:
#7
Size:
4 000 µm
Distribution:
0 %

Any other information on results incl. tables

NA

Applicant's summary and conclusion

Conclusions:
The particle size distribution of the AVE 5530 EVA-KET was found to be [250 µm; 2000 µm].
Executive summary:

The particle size distribution of the AVE 5530 EVA-KET was found to be [250 µm; 2000 µm].