Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 May 2014 to 29 August 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
- Physical state: white powder
- Analytical purity: 94.3% (w/w)
- Batch number: 93138112
- Expiry date: 16 February.2015
- Date of certificate: 20 Februara 2014
- Storage conditions: ambient (+5 to +30°C), dark, dry
Mass median aerodynamic diameter:
ca. 12.6 µm
Remarks on result:
other: Standard deviation
Remarks:
Geometric standard deviation was not measured in the test
Key result
Percentile:
D10
Mean:
1.8 µm
Remarks on result:
other: Geometric standard deviation
Remarks:
Geometric standard deviation was not measured in the test.
Key result
Percentile:
D50
Mean:
12.6 µm
Remarks on result:
other: Geometric standard deviation
Remarks:
Geometric standard deviation was not measured in the test.
Key result
Percentile:
D90
Mean:
34 µm
Remarks on result:
other: Geometric standard deviation
Remarks:
Geometric standard deviation was not measured in the test.
No.:
#1
Size:
>= 1.775 - <= 1.802 µm
Distribution:
10 %
No.:
#2
Size:
>= 12.517 - <= 12.695 µm
Distribution:
50 %
No.:
#3
Size:
>= 33.825 - <= 34.143 µm
Distribution:
90 %
Conclusions:
L10D(v,0.1):1.8 µmL50D(v,0.5):12.6 µmL90D(v,0.9):34.0 µm
Executive summary:

The particle size distribution of Captan was determined according to CIPAC MT 187.

The optical observation of the test item is depicted in the following table.

Determined particle size range:

L10D(v,0.1)

1.8 µm

L50D(v,0.5)

12.6 µm

L90D(v,0.9)

34.0 µm

Description of key information

Particle size distribution (optical observation), determined particle size range: L10D(v,0.1): 1.8 µm; L50D(v,0.5): 12.6 µm; L90D(v,0.9): 34.0 µm, Guideline CIPAC MT 187

Additional information

Medium particle size was determined to be 12.6 µm according to CIPAC MT 187 method. Particle size has to be considered for choosing the right PPE (personal protection equipment) for inhalation exposure.