Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 201-222-2 | CAS number: 79-74-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 04 August 2016 to 04 October 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Version / remarks:
- European Community (EC), EC no. 260/2014, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.6: “Water Solubility”, Official Journal of the European Union no. L81, March 19, 2014.
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- Organization for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals no. 105: "Water Solubility", July 27, 1995.
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7840 (Water Solubility)
- Version / remarks:
- United States Environmental Protection Agency (EPA), Product Properties Test Guidelines no. OPPTS 830.7840: "Water Solubility: Column Elution Method; Shake Flask Method", March 1998.
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Specific details on test material used for the study:
- No further details specified in the study report
- Key result
- Water solubility:
- < 0.2 µg/L
- Conc. based on:
- test mat.
- Temp.:
- 20 °C
- pH:
- >= 6.3 - <= 6.4
- Details on results:
- Test item was detected at either flow rate only below the concentration of the lowest calibration standard. The analysed concentrations are, therefore, reported as below the lowest calibration standard, multiplied by the dilution factor.
Test item was detected when the loaded column material was analysed. This proved that the column was not depleted when the water solubility samples were taken.
The turbidity of the eluates was < 0.2 NTU. According to this, no undissolved particles were detected in the eluates.
Test item was detected below the concentration of the lowest calibration standard from the blank column in samples collected at a flow rate of 24 mL/h. At a rate of 12 mL/h no test item was detected in the samples from the blank column. - Conclusions:
- The column elution method was applied for the determination of the water solubility of Lowinox® AH25.
The water solubility of the test item at 20°C was < 0.2 μg/L. The pH of the aqueous samples was 6.3 – 6.4. - Executive summary:
The purpose of the study was to determine the following physico-chemical properties for Lowinox® AH25:
-Water solubility
The study was performed in accordance with the following guidelines:
European Community (EC), EC no. 260/2014, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.6: “Water Solubility”, Official Journal of the European Union no. L81, March 19, 2014.Organization for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals no. 105: "Water Solubility", July 27, 1995.
United States Environmental Protection Agency (EPA), Product Properties Test Guidelines no. OPPTS 830.7840: "Water Solubility: Column Elution Method; Shake Flask Method", March 1998.
Two methods are available for the determination of the water solubility of a solid test item: Flask method and Column elution method. As determined in project 494311 the water solubility of the test item was < 0.08 mg/L. Accordingly the column elution method was carried out.
The column elution method was applied for the determination of the water solubility of Lowinox® AH25.
The water solubility of the test item at 20°C was < 0.2 μg/L. The pH of the aqueous samples was 6.3 – 6.4.
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- 22 June 2010-13 September 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: This study has been performed according to OECD and EC guidelines and according to GLP principles.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Key result
- Water solubility:
- < 0.08 mg/L
- Temp.:
- 20 °C
- pH:
- 7.5
- Remarks on result:
- other: The limit of detection (LOD) was determined to be 0.08 mg/l taking a dilution factor of two into account.
- Conclusions:
- Interpretation of results (migrated information): insoluble (< 0.1 mg/L)
The column elution method was chosen for the determination of the water solubility of Lowinox® AH25. The water solubility of the test substance at 20°C was < 0.08 x 10-3 g/l. The pH of the aqueous samples was 7.5. - Executive summary:
The aim of the study was to determine the following physico-chemical properties for Lowinox® AH25: Water solubility in accordance with the following guidelines:
Organization for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals no. 105: "Water Solubility", July 27, 1995.
European Community (EC), EC no. 440/2008, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.6: "Water Solubility", Official Journal of the European Union no. L 142, May 31, 2008.
A preliminary test was carried out as a range-finding test prior to performance of the column elution method or flask method.
Preliminary test
Test substance was stirred with double distilled water at a nominal concentration of 0.108 g/l at 20.1 ± 0.5 °C for 22 hours (1 day). After stirring, the water phase was centrifuged, treated and analysed. The centrifugation method was checked and was found to be sufficient to remove all undissolved test substance.
In the preliminary test the water solubility of the test substance was < 10-2 g/l. Therefore, the column elution method was chosen for the main study.
Main study
A solution with an absolute test substance quantity of 65.8 mg was prepared in acetone. The solution was mixed with 5 g LiChroprep Si 100 25-40 μm column material (Merck, Darmstadt, Germany). Acetone was completely evaporated at 40°C using a rotary evaporator. The loaded carrier material was stored at room temperature, prior to use. A 150 mm x 4.6 mm i.d. column was filled with the carrier material and 0.5 μm frits were used to enclose the column. Double distilled water was pumped through the column until it was completely filled. The system was allowed to equilibrate for two hours.
After the equilibration period, the column was eluted overnight with double distilled water at a flow rate of 12 ml/hour. The following day the flow was increased to 24 ml/hour. Ten consecutive samples of 2 ml were taken. The flow was halved to 12 ml/hour and ten consecutive samples of 2 ml were taken. The samples were diluted in a 1:1 (v:v) ratio with methanol and analysed.
After sampling, the remaining parts of the water samples were combined for pH measurement.
The pH was measured from the water fractions that were collected for the determination of the flow rates.
The eluates were checked for the presence of undissolved particles by examination for the Tyndall effect (light scattering). This was performed by recording an UV-Vis absorption spectrum between 200 nm and 900 nm.
The experiment was also performed using a column filled with blank carrier material. The procedure was identical to the procedure used for the column loaded with test substance. At each flow rate, two consecutive samples were taken for analyses.
The test was performed in a climate room where the temperature was 20.4 °C ± 0.6 °C.
Results
Preliminary test
The content of test substance dissolved in the water sample was 2.14 x 10-3 g/l.
Main study
The coefficient of variation (CV) (n = 10) was < 30% at both flow rates. The maximum difference (MD) on the water solubility was also < 30%. Therefore, the water solubility of the test substance was given as the mean value of the measurements at both flow rates. No undissolved particles were detected in the eluates using the Tyndall effect. No test substance was detected in the samples from the blank column. After the performance of the study it was confirmed that test substance was still present on the test substance column.
Conclusion
The column elution method was chosen for the determination of the water solubility of Lowinox® AH25. The water solubility of the test substance at 20 °C was < 0.08 x 10-3 g/l. The pH of the aqueous samples was 7.5.
Referenceopen allclose all
Main Study – water solubility of the test item
Flow rate [mL/h] |
Sample no. |
Concentration analysed |
pH |
||||
Individual [μg/L] |
Mean1 [μg/L] |
CV [%] |
Mean1 [μg/L] |
MD [%] |
|||
24 |
1 2 3 4 5 6 7 8 9 10 |
<0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 |
<0.20 |
n.a. |
<0.20 |
n.a. |
6.3 |
12 |
1 2 3 4 5 6 7 8 9 10 |
<0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 <0.20 |
<0.20 |
n.a. |
|
|
6.4 |
1Mean of the concentrations was below the lowest calibration standard, taking the dilution factor of 2 into account.
Preliminary test
The content of test substance dissolved in the water sample was 2.14 x10-3 g/l.
Main study:
The water solubility of the test substance was given as the mean value of the measurements at both flow rates. No test substance was detected in the water samples. The limit of detection (LOD) was determined to be 0.08 mg/l taking a dilution factor of two into account.
No test substance was detected in the samples from the blank column.
No undissolved particles were detected in the eluates using the Tyndall effect.
Description of key information
The column elution method was applied The water solubility of the test item at 20°C was < 0.2 μg/L.
Key value for chemical safety assessment
- Water solubility:
- 0.2 µg/L
- at the temperature of:
- 20 °C
Additional information
Key Study
Two methods are available for the determination of the water solubility of a solid test item: Flask method and Column elution method. As determined in project 494311 the water solubility of the test item was < 0.08 mg/L. Accordingly the column elution method was carried out.
The column elution method was applied for the determination of the water solubility of Lowinox® AH25.
The water solubility of the test item at 20°C was < 0.2 μg/L. The pH of the aqueous samples was 6.3 – 6.4.
Supporting Study
A preliminary test was carried out as a range-finding test prior to performance of the column elution method or flask method.
In the preliminary test the water solubility of the test substance was < 10-2 g/l. Therefore, the column elution method was chosen for the main study.
Results
Preliminary test: The content of test substance dissolved in the water sample was 2.14 x 10-3 g/l.
Main study: The coefficient of variation (CV) (n = 10) was < 30% at both flow rates. The maximum difference (MD) on the water solubility was also < 30%. Therefore, the water solubility of the test substance was given as the mean value of the measurements at both flow rates. No undissolved particles were detected in the eluates using the Tyndall effect. No test substance was detected in the samples from the blank column. After the performance of the study it was confirmed that test substance was still present on the test substance column.
The column elution method was chosen for the determination of the water solubility of Lowinox® AH25. The water solubility of the test substance at 20 °C was < 0.08 x 10-3 g/l. The pH of the aqueous samples was 7.5.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.