First-aid measures

Description of first aid measures

General information

Personal protection for the First Aider.

Take affected persons out of danger area and instruct to lie down.

Instantly remove any clothing soiled by the product.

After inhalation

Supply fresh air.

In case of unconsciousness bring patient into stable side position for transport.

Seek medical treatment

After skin contact

Instantly wash with water and soap and rinse thoroughly.

Seek medical treatment.

After eye contact

Rinse opened eye for several minutes under running water.

Seek medical treatment.

After swallowing

Rinse out mouth and then drink plenty of water.

Do not induce vomiting; instantly call for medical help.

Most important symptoms and effects, both acute and delayed

No further relevant information available.

Information for doctor Therapeutically measures: basic help, decontamination, symptomatic treatment.

Indication of any immediate medical attention and special treatment needed

No further relevant information available.

Fire-fighting measures

Extinguishing media

Suitable extinguishing agents

CO2, extinguishing powder or water jet. Fight larger fire with foam.

For safety reasons unsuitable extinguishing agents

Water with a full water jet.

Special hazards arising from the substance or mixture

Can be released in case of fire

Carbon monoxide (CO)

Advice for firefighters

Protective equipment:

Do not inhale explosion gases or combustion gases.

Wear self-contained breathing apparatus.

Additional information

Cool endangered containers with water spray jet.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental precautions:

Do not allow to enter drainage system, surface or ground water.

Methods and material for containment and cleaning up:

Ensure adequate ventilation.

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Send for recovery or disposal in suitable containers.

Reference to other sections

- See Section "Handling and storage" for information on safe handling

- See Section "Exposure controls/personal protection" for information on personal protection equipment.

- See Section "Disposal considerations" for information on disposal.

Handling and storage

Precautions for safe handling

Ensure good ventilation/exhaustion at the workplace.

Prevent formation of aerosols.

Information about protection against explosions and fires:

Keep ignition sources away - Do not smoke.

Protect against electrostatic charges.

Conditions for safe storage, including any incompatibilities

Storage

Requirements to be met by storerooms and containers: Storehouses and workplaces must be sufficiently ventilated.

Information about storage in one common storage facility: Store away from oxidizing agents.

Further information about storage conditions: Keep container tightly sealed.

Specific end use(s) No further relevant information available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls

Personal protective equipment

General protective and hygienic measures

The usual precautionary measures should be adhered to general rules for handling chemicals.

Use skin protection cream for preventive skin protection.

Be sure to clean skin thoroughly after work and before breaks.

Take off immediately all contaminated clothing

Wash hands during breaks and at the end of the work.

Store protective clothing separately.

Breathing equipment:

In case of brief exposure or low pollution use breathing filter apparatus . In case of intensive or longer exposure use breathing apparatus that is independent of circulating air.

Filter ABEK-P3

Protection of hands:

Only use chemical-protective gloves with CE-labelling of category III (EN 374).

Material of gloves

Nitrile rubber

. Recommended thickness of the material: ≥ 0,425 mm

. Value for the permeation: > 480 min

Fluorocarbon rubber (Viton) / Butyl rubber

. Recommended thickness of the material: ≥ 0,7 mm

. Value for the permeation: > 480 min

The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

Penetration time of glove material

The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory) gloves made of the following material are suitable:

Butyl rubber, BR

Nitrile rubber, NBR

Eye protection:

Tightly sealed safety glasses.

Gauze goggles

Body protection:

Protective work clothing.

Stability and reactivity

Reactivity

No further relevant information available.

Chemical stability

Thermal decomposition / conditions to be avoided:

No decomposition if used according to specifications.

Possibility of hazardous reactions Violent reaction with water at high temperatures

Conditions to avoid No further relevant information available.

Incompatible materials: No further relevant information available.

Hazardous decomposition products: No dangerous decomposition products known

Disposal considerations

Waste treatment methods

Recommendation Remove according to local authority recommendations, e.g. convey to a suitable incinerator.

European waste catalogue

The disposal of waste within the EU is regulated by Directive 2008/98/EC

The waste code classification is to be carried out according to the European Waste Catalogue (EWC) specifically for each branch of industry and each type of process.

Uncleaned packagings:

Recommendation: Disposal must be made according to official regulations.