Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Substance ID: F6TF
Lot #: 8922/16
Purity: 99.7%
Key result
Flash point:
50 °C
Atm. press.:
747 mm Hg
Remarks on result:
other: Flash Point = 50 ± 2°C; the substance is classified as flammable in terms of its flashpoint.

Test Temperature (°C)

Flash Detected

50

Yes

49

No

50

Yes

49

No

 

Conclusions:
This study and the conclusions which are drawn from it fulfil the quality criteria (validity, reliability, repeatability).
Flash Point = 50 ± 2°C
Executive summary:

The flash point test was carried out in accordance with Test A.9, using ASTM D3828-93 for small scale (Setaflash) closed-cup testing. The flash point was determined to be 50 ± 2°C; therefore, the test substance is considered flammable.

Description of key information

50 ± 2°C at 747 mm Hg

Key value for chemical safety assessment

Flash point at 101 325 Pa:
50 °C

Additional information

The flash point of the test substance is 50°C and istherefore considered to be aFlammable Liquid - Category 3 underClassification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008 and ATP01. Annex VI Index number 613-245-00-9 and R10under Directive 67/548/EEC classification and labelling in Annex I.