Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-10-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point:
124 °C
Atm. press.:
1 013 mBar
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point for Tetrabutane is 124°C at 1013 mbar.
Executive summary:

Flash point for Tetrabutane is 124°C at 1013 mbar.

Description of key information

Flash point for Tetrabutane is 124°C at 1013 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
397 K

Additional information

Flash point for Tetrabutane is 124°C at 1013 hPa.

Categories Display