Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: Acc. DGF-Einheitsmethode, H-II 2 (65)
GLP compliance:
no
Type of method:
sieving
Type of distribution:
mass based distribution
Remarks on result:
not measured/tested
Percentile:
D10
Mean:
175 µm
Remarks on result:
other: standard deviation not stated
Percentile:
D50
Mean:
315 µm
Remarks on result:
other: standard deviation not stated
Percentile:
D90
Mean:
470 µm
Remarks on result:
other: standard deviation not stated

   Measurement
> 1000 µm  1.23 %
> 800 µm  1.14 %
> 500 µm  17.14 %
> 400 µm  33.34 %
> 300 µm  32.86 %
> 200 µm  10.24 %
> 100 µm  3.32 %
> 63 µm  0.13 %
< 63 µm  0.00 %

 Median diameter  
 D 10%  175 µm
 D 50%  315 µm
 D 90%  470 µm
Conclusions:
The D10, D50 and D90 of the PSD of octanoic acid, zinc salt, basic (i.e., Stabiol ZN 1950, batch 11 K 5703) are 175 µm, 315 µm, and 470 µm, respectively.
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
DIN 55992-1 (Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method)
Version / remarks:
2006
Deviations:
yes
Remarks:
Heubach dust meter is modified by using 7 stage cascade impactor connected to the system. This involves an add. air fed of 20 L/min via coarse dust separator to supply the impactor with 40 L/min air current as specified in manufacturer’s specifications.
GLP compliance:
no
Type of method:
cascade impaction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
32.58 µm
Geometric standard deviation:
1.52
Percentile:
D50
Remarks on result:
not measured/tested

Dustiness (airborne fraction): total: 55.23 mg/g.

In the original study report by DMT, a calculation of the mass median diameter was not conducted. Since the deposited fractions were provided for each of the cascade impactor stages, it was possible to fit a mono modal lognormal distribution to the databy standard non-linear regression procedure. As a result, the MMAD and GSD of total dustiness (airborne) fraction are calculable and reported (MMAD = 32.58 µm, GSD = 1.52). As the cascade impactor already takes aerodynamic characteristics of the particles into account, the reported mass median diameter can be interpreted as the mass medianaerodynamicdiameter.

This figure and the corresponding GSD were used as distribution parameters for the MPPD model enabling an estimation of deposited dust fractions in the human respiratory tract: These fractions were estimated as follows:

Head (ET): 40.3%

Tracheobronchial (TB): 0.0%

Pulmonary (PU): 0.0%

Conclusions:
Total Dustiness (airborne fraction): 55.23 mg/g (experimental results, DMT Report).

Mass median aerodynamic diamater of total dustiness (airborn) fraction: MMAD = 32.58 µm (distribution fitted to cascade impactor data).
Geometric standard deviation of MMAD: GSD = 1.52

Fractional deposition in human respiratory tract (MPPD model, based on calculated MMAD):
Head (ET): 40.3 %
Tracheobronchial (TB): 0.0 %
Pulmonary (PU): 0.0 %

Description of key information

The granulometry of a representative sample of Octanoic acid, zinc salt, basic is:

Particle size Distribution (Hernandez Blanco, 2011-2012)

- D10: 175 µm

- D50: 315 µm

- D90: 470 µm

Dustiness (Parr, Grewe, 2012):

-Total Dustiness (airborne fraction): 55.23 mg/g

- MMAD = 32.58 µm (distribution fitted to cascade impactor data).

-  GSD = 1.52

- Fractional deposition in human respiratory tract (MPPD model, based on calculated MMAD):

Head (ET): 40.3 %

Tracheobronchial (TB): 0.0 %

Pulmonary (PU): 0.0 %

Additional information

Particle size Distribution (Hernandez Blanco, 2011-2012)

The D10, D50 and D90 of the PSD of octanoic acid, zinc salt, basic (i.e., Stabiol ZN 1950, batch 11 K 5703) are 175 µm, 315 µm, and 470 µm, respectively.

Dustiness (Parr, Grewe, 2012)

Total Dustiness (airborne fraction): 55.23 mg/g (experimental results, DMT Report).

Mass median aerodynamic diameter of airborne fraction: MMAD = 32.58 µm (distribution fitted to cascade impactor data).

Geometric standard deviation of MMAD: GSD = 1.52

Fractional deposition in human respiratory tract (MPPD model, based on calculated MMAD):

Head (ET): 40.3 %

Tracheobronchial (TB): 0.0 %

Pulmonary (PU): 0.0 %