Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

In an Activated Sludge Respiration Inhibition Test according to OECD guideline 209, the 3-h EC50 of the read across substance Reaction products of γ-butyrolactone, naphthalene-1,6-diol and phthalic anhydride (EC 946-798-2) was determined to be > 1000.0 mg/L. The 3-h EC10 of the read across substance was determined to be 630.0 mg/L.

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L
EC10 or NOEC for microorganisms:
630 mg/L

Additional information

No data on toxicity to aquatic microorganisms were available for the substance itself. Therefore, a read across to the close structural analogue Reaction products of γ-butyrolactone, naphthalene-1,6-diol and phthalic anhydride (EC946-798-2) was conducted.

Key study

To assess the effects of the close structural analogue (EC946-798-2) on the oxygen consumption of municipal activated sludge, an Activated Sludge Respiration Inhibition Test according to OECD guideline 209 and EU Method C.11 was conducted in compliance with GLP principles. Activated sludge from a municipal wastewater treatment plant was exposed for 3 hours to nominal concentrations of 1000, 500, 250, 125 and 62.5 mg/L of the close structural analogue (based on the analogue without correction of purity and blank controls; 3 replicates for each concentration). The analogue was weighed in the required amounts for the test concentrations directly to the test vessels. A blank control (with 6 replicates) and a positive control with the reference substance 3,5-dichlorophenol (with 2 replicates for each concentration; 100, 10, 1 mg/L) was performed in parallel. The initial sludge concentration in the test vessels was 1.5 g/L dw. The consumption rate (mg O2/L*x minutes) of each test concentration and the blank controls were determined after 3 hours of exposure. The oxygen consumption was measured over a period of 8 -10 minutes. 6 to 6.3 minutes from the plotted track within a linear range of the graph was used for the determination of the respiration rate. The consumption rates (mg O2/L*h) were used to calculate the inhibition effects at particular test concentrations compared to the mean consumption rate of all controls. In result, the 3-h EC10 was determined to be 630 mg/L; the 3-h EC20, EC50 and EC80 was determined to be >1000 mg/L. The coefficient of variation of the six replicates of blank control was 7.7 % O2 consumption. Furthermore. the 3-h EC50 of 3,5-dichlorophenol was 3.8 mg/L and the mean oxygen uptake of the blank controls was 23 mg/g*h. In conclusion, the test conformed to all validity criteria and is valid.