Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 Oct 2020 to 04 Dec 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N-{5-[(4-{4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl}pyrimidin-2-yl)amino]-4-methoxy-2-(morpholin-4-yl)phenyl}prop-2-enamide
EC Number:
841-500-6
Cas Number:
1903008-80-9
Molecular formula:
C30H34N8O3
IUPAC Name:
N-{5-[(4-{4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl}pyrimidin-2-yl)amino]-4-methoxy-2-(morpholin-4-yl)phenyl}prop-2-enamide
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- lot/batch number of test material: M20BD0542
- Expiry date: 19 February 2022 (retest date)
- Physical Description: Slightly greenish yellow powder
- Purity: 99.8%
- Purity correction factor: 1.00

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
1 s

Any other information on results incl. tables

The flame of the gas burner did ignite the test item pile. The test item melted, burned with a yellow flame and turned into a red/black residue. White smoke was observed. After removal of the ignition source, the flame extinguished after 1 second and no propagation of combustion was observed.

Applicant's summary and conclusion

Conclusions:
The preliminary screening test was performed for the determination of the flammability of JNJ-73841937-AAA (T003925).
No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes
was observed. According to the guidelines, performance of the burning rate test is not required.
Based on the results obtained, the test item should be considered ‘not flammable’ according to the classification criteria under Regulation (EC) No 1272/2008 for flammable solids.