Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 February 2017 - 10 February 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
2013
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N-{[1,1'-biphenyl]-4-yl}-N-[2-(9,9-diphenyl-9H-fluoren-4-yl)phenyl]-9,9-dimethyl-9H-fluoren-2-amine
EC Number:
811-852-5
Cas Number:
1792219-00-1
Molecular formula:
C58H43N
IUPAC Name:
N-{[1,1'-biphenyl]-4-yl}-N-[2-(9,9-diphenyl-9H-fluoren-4-yl)phenyl]-9,9-dimethyl-9H-fluoren-2-amine
Test material form:
solid: particulate/powder

Test animals / tissue source

Species:
cattle
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: OdenwaldschlachthofBrensbach, 64395 Brensbach, Germany
- Characteristics of donor animals: 21 - 191 months
- Storage, temperature and transport conditions of ocular tissue (e.g. transport time, transport media and temperature, and other conditions): The eyes were kept and transported in transport medium cooled on ice.
- Time interval prior to initiating testing: The corneas were prepared immediately after delivery of the eyes to the laboratory.
- indication of any existing defects or lesions in ocular tissue samples: Any corneas that showed macroscopic tissue damage (e.g. scratches, pigmentation, neovascularization) or an opacity >7 opacity units were discarded.

Test system

Vehicle:
physiological saline
Controls:
yes, concurrent vehicle
yes, concurrent positive control
Amount / concentration applied:
TEST MATERIAL
- Amount applied: 750 µL of the suspended test item (i.e. 150 mg/750 µL)
- Concentration: 20% (w/v) suspension in a 0.9% sodium chloride solution

VEHICLE
- Amount applied: 750 µL

Duration of treatment / exposure:
240 min
Number of animals or in vitro replicates:
3
Details on study design:
SELECTION AND PREPARATION OF CORNEAS
Freshly isolated bovine eyes of cattle were collected from the slaughterhouse. Excess tissue was removed from the eyes. The eyes were kept and transported in transport medium cooled on ice. The corneas were prepared immediately after delivery of the eyes to the laboratory. All eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity or scratches were discarded. The corneas were carefully removed from the eyes using scalpel and rounded scissors. A rim of about 2 to 3 mm of tissue (sclera) was left for stability and handling of the isolated cornea. All corneas used in the study were collected in incubation medium (pre-warmed at 32 ± 1°C) and the corneal diameter of each cornea was measured and recorded.
Each cornea was mounted in a cornea holder (CiToxLAB, Veszprem, Hungary) with the endothelial side against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring without Stretching the cornea. Afterwards, the anterior part of the holder was positioned on top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex form.

QUALITY CHECK OF THE ISOLATED CORNEAS
For equilibration, the corneas in the holder were incubated (BSS 160, Grumbach Brutgeräte GmbH, Asslar, Germany) in a vertical position at 32 ± 1°C for about one hour. At the end of the incubation period, the incubation medium was replaced by fresh pre-warmed
(32 ± 1°C) incubation medium in both compartments. The baseline opacity was determined with a calibrated opacitometer (BASF-OP2.0, BASF SE, Ludwigshafen, Germany). The light transmission through the corneas, given as lux value, was recorded in a table and thereafter converted into an opacity value (baseline opacity values). Any corneas that showed macroscopic tissue damage (e.g. scratches, pigmentation, neovascularization) or an opacity >7 opacity units were discarded. Three corneas were selected as negative control corneas. The remaining corneas were distributed into treatment and positive control group.

NUMBER OF REPLICATES: 3

NEGATIVE CONTROL USED: No

SOLVENT CONTROL USED: 0.9% sodium chloride solution

POSITIVE CONTROL USED : Imidazole

APPLICATION DOSE AND EXPOSURE TIME : 750 µL of the suspended test item (i.e. 150 mg/750 µL) and 240 min

TREATMENT METHOD: closed chamber (solvent and positive control); open chamber (test item)

POST-INCUBATION PERIOD: no.

REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: To remove the test item from the epithelium, the window locking-ring and the glass window from the anterior chamber were removed. The corneas were gently rinsed with wash medium using a syringe. Before measurement of the opacity value after treatment, fresh incubation medium was replaced in both compartments. To remove thesolvent and positive control, the corneal surface was washed three times.

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: calibrated opacitometer (BASF-OP2.0, BASF SE, Ludwigshafen, Germany)
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of microtiter plate reader (OD490)
- Others: Each cornea was observed visually and pertinent observations were recorded (e.g. tissue peeling, residual test chemical, non-uniform opacity patterns)

SCORING SYSTEM: In Vitro Irritancy Score (IVIS)

DECISION CRITERIA: IVIS <= 3 (no UN GHS category), IVIS > 3; <= 55 (No prediction can be made), IVIS > 55 (UN GHS category 1)

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
in vitro irritation score
Run / experiment:
Cornea 1
Value:
0.315
Vehicle controls validity:
valid
Negative controls validity:
not examined
Positive controls validity:
valid
Irritation parameter:
in vitro irritation score
Run / experiment:
Cornea 2
Value:
1.815
Vehicle controls validity:
valid
Negative controls validity:
not examined
Positive controls validity:
valid
Irritation parameter:
in vitro irritation score
Run / experiment:
Cornea 3
Value:
3.385
Vehicle controls validity:
valid
Negative controls validity:
not examined
Positive controls validity:
valid
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: No

DEMONSTRATION OF TECHNICAL PROFICIENCY: Yes

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: Yes
- Acceptance criteria met for positive control: Yes

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is not requiring classification for eye irritation or serious eye damage (UN GHS: No Category).
Executive summary:

The objective of the present study was to exarnine the potential of the test itern to induce serious eye darnage in the BCOP assay. The BCOP assay with isolated fresh bovine corneas is an accepted in vitro rnodel for ocular hazard assessrnent.

To deterrnine the eye hazard potential the induced opacity and increased perrneability was investigated in isolated bovine corneas after exposure to the test itern as a 20% (w/v) suspension in a 0.9% sodiurn chloride solution. As negative control 0.9% sodiurn chloride solution and as positive control 20% (w/v) lmidazole was used. Three corneas were used per group (negative control, positive control ortest itern group). The incubation time was 240 min. After the opacity measurements, the permeability of the corneas was determined by application of a fluorescein solution for 90 rninutes. The amount of fluorescein solution that crossed the cornea was measured spectrophotometrically. The opacity and permeability assessments were combined to determine an In Vitro lrritancy Score (IVIS). The study fulfilled the acceptance criteria.

The IVIS obtained after treatrnent with the test item was 1.8 and, thus, lower than 3, i.e. according to OECD 437 the test item is not requiring classification for eye irritation or serious eye damage (UN GHS: No Category).