Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 Dec 2015 - 10 Dec 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
no
Type of method:
column elution method

Test material

Constituent 1
Chemical structure
Reference substance name:
N-{[1,1'-biphenyl]-4-yl}-N-[2-(9,9-diphenyl-9H-fluoren-4-yl)phenyl]-9,9-dimethyl-9H-fluoren-2-amine
EC Number:
811-852-5
Cas Number:
1792219-00-1
Molecular formula:
C58H43N
IUPAC Name:
N-{[1,1'-biphenyl]-4-yl}-N-[2-(9,9-diphenyl-9H-fluoren-4-yl)phenyl]-9,9-dimethyl-9H-fluoren-2-amine
Test material form:
solid: particulate/powder

Results and discussion

Water solubility
Key result
Water solubility:
< 0.1 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
ca. 6

Any other information on results incl. tables

Preliminary results

Three preliminary tests were carried out with specified amounts of the test item and 100 mL and 500 mL distilled water, respectively. After each addition of an amount of water, the mixture was stirred for at least 24 hours, and visually checked for any undissolved particles. The solubility of the test item in water was found to be below 9.2 mg/L (without correction for the purity). According to the guideline the column elution method is the appropriate method for solubilities below 10 mg/L. Therefore, this method was used for the main test.

Applicant's summary and conclusion

Conclusions:
The water solubility of the test item at a temperature of 20°C was found to be less than 0.1 mg/L and thus below the quantification limit.