Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01-12-2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature
Interpretation of results:
GHS criteria not met
Conclusions:
No flash point was observed up to the boiling of the substance.
Executive summary:

A study was conducted to determine the flash point of the test subtance according to EEC method A.9 under GLP conditions. The Pensky-Martens closed cup method was used. The substance has not flash point up to the boiling point of the test item.

Description of key information

Key study: Test method according to EEC A.9. GLP study. The test item has no flash point up to the boiling point of the substance.

Key value for chemical safety assessment

Additional information