Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
no guideline followed
Principles of method if other than guideline:
HSE Guidance
GLP compliance:
yes
Type of method:
other: Particle size analyzer
No.:
#6
Size:
< 180 µm
Distribution:
11.1 %
No.:
#1
Size:
> 57.84 µm
Distribution:
10 %
No.:
#2
Size:
> 51.81 µm
Distribution:
25 %
No.:
#3
Size:
> 25.71 µm
Distribution:
50 %
No.:
#4
Size:
> 14.71 µm
Distribution:
75 %
No.:
#5
Size:
> 9.308 µm
Distribution:
90 %
Conclusions:
Approximately 11.1% of the particles were less than 180 µm by sieving. The particles that were less than 180 µm had the following particle size distribution: 10% > 57.84, 25% > 51.81, 50% > 25.71, 75% >14.71, and 90% >9.308 µm.
Executive summary:

Granulometry measurements have been conducted. Approximately 11.1% of the particles were less than 180 µm by sieving. The particles that were less than 180 µm had the following particle size distribution: 10% > 57.84, 25% > 51.81, 50% > 25.71, 75% >14.71, and 90% >9.308 µm.

Description of key information

HSE Guidance

Additional information

11.1%  <180 µm

Distribution: 10% >57.84 µm, 25% >51.81 µm, 50% >25.71 µm, 75% >14.71 µm, 90% >9.308 µm