Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
yes
Remarks:
See principles of method if other than guideline field.
Principles of method if other than guideline:
The guideline does not contain relevant information for surface active substances.
The samples were not shaken for 24 hours before letting them stand to let the phases separate.
Test didn't have 3 different volume ratio of n-octanol to water.
GLP compliance:
no
Type of method:
flask method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
> 1.4 - <= 1.5
Temp.:
22 °C
pH:
1
Conclusions:
Log Pow octanol-water partition coefficient of test item was determined greater than 1.4 less than or equal to 1.5 at 22ºC.
Executive summary:

The partition coefficient test was done according to OECD guideline 107 without GLP compliance. Log Pow octanol-water partition coefficient of test item was determined greater than 1.4 less than or equal to 1.5 at 22ºC.

Description of key information

The partition coefficient test was done according to OECD guideline 107 without GLP compliance. Log Pow octanol-water partition coefficient of test item was determined greater than 1.4 less than or equal to 1.5 at 22ºC.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.5
at the temperature of:
22 °C

Additional information